Ferrum
PackagesBooksPeriodic Table
Maarif
Dashboard
Dashboard
← Chemistry Lab

Measure how concentration affects the rate of reaction

Drop magnesium ribbon into HCl solutions of different concentrations, measure the hydrogen gas given off and compare the times.

Equipment and chemicals

  • Conical flask (250 mL): A cone-shaped glass flask with a narrow neck. It stands under the funnel to collect the filtrate.
  • Gas syringe: Fits into the neck of the conical flask with its stopper and measures the volume of gas given off in a reaction.
  • HCl solution (1 mol/L): A strong acid solution of known concentration.
  • Distilled water (wash bottle): Adds the amount of distilled water you choose.
  • Magnesium ribbon: A metal that reacts with acid and gives off hydrogen gas. Each addition drops in 0.05 g of ribbon.
  • Thermometer: Shows the temperature of the liquid it is dipped into.

Method

Put 50 mL of 1 mol/L HCl solution in the conical flask.

Select the HCl bottle, check that the amount is 50 mL and drag it onto the conical flask.

Fit the gas syringe into the neck of the conical flask.

Drag the gas syringe onto the conical flask.

Add magnesium ribbon and wait until no more gas is given off.

Drag the Mg jar onto the conical flask. Watch the volume of gas grow on the graph.

Empty the flask; this time put in 25 mL of HCl and 25 mL of water (0.5 mol/L).

Select the conical flask and press “Empty”. Set the amount of both the HCl bottle and the wash bottle to 25 mL and add both to the flask.

Add magnesium again and compare the time with your first run.

Drag the Mg jar onto the conical flask and wait for the reaction to finish.

Safety in a real lab

Mistakes do no harm on the virtual bench. In a real lab, do this experiment only under your teacher’s supervision and follow these rules:

  • Wear safety goggles, a lab coat and gloves; 1 mol/L hydrochloric acid irritates skin and eyes.
  • The hydrogen given off is a flammable gas. Keep flames and sparks away and work in a ventilated room.
  • Check beforehand that the plunger of the gas syringe moves freely; a stuck plunger can blow the stopper out.

Why does it happen?

The rate of reaction is the amount of substance used up or formed per unit time. In the reaction between magnesium and hydrochloric acid, the rate is followed by measuring the volume of hydrogen gas given off against time: Mg + 2 HCl → MgCl₂ + H₂.

According to collision theory, particles must collide with enough energy and in the right orientation to react. When the concentration of the acid increases, there are more H⁺ ions per unit volume, so more ions hit the magnesium surface per unit time and the reaction speeds up.

When you halve the concentration, the reaction takes about twice as long. The total volume of gas does not change, because it is set by the amount of magnesium, the limiting reagent. If you heat the solution, the average kinetic energy of the particles increases and the reaction speeds up again.

Related tools

  • Balance the Mg + HCl reaction with the equation balancer
  • Calculate the moles of magnesium with the mol calculator

Frequently asked questions

How does concentration affect the rate of reaction?

As concentration increases, the number of particles per unit volume and the number of successful collisions per unit time increase, so the reaction speeds up.

Does the amount of gas change when the concentration changes?

Not if the acid is in excess. The amount of hydrogen is set by the magnesium, the limiting reagent; the concentration only affects how long it takes for the gas to be given off.

What else increases the rate of reaction?

Raising the temperature, increasing the surface area of a solid (using it as a powder) and adding a catalyst all speed up a reaction.

More experiments

Ferrum

Free chemistry tools, simulations and personalized study tracking for exam prep.

Core Tools

BooksPeriodic TableElement Quiz

© 2026 Ferrum. All rights reserved.
About UsPrivacy PolicyWhatsApp Contact
Free Chemistry Platform · ferrumone.com